Spelsberg WKE AK Малые распределительные щиты пожаростойкие F90
Основные характеристики |
|||
|
|
||
Перечень продукции |
Артикул |
Наименование |
Габариты |
Стенки |
Описание |
86541401 |
WKE AK 14 |
400 x 540 x 230 мм |
stop left, 1-row, 14 distribution units, Ui=400V, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 14 screwless terminal points, 1.5 - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86551401 |
WKE AK 14 R |
400 x 540 x 230 мм |
Stop right, 1-row, 14 distribution units, Ui=400V, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 14 screwless terminal points, 1.5 - 16 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86542801 |
WKE AK 28 |
400 x 690 x 230 мм |
stop left, 2 row, 28 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points 1.5 - 4 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86552801 |
WKE AK 28 R |
400 x 690 x 230 мм |
Stop right, 2 row, 28 modules, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points 1.5 - 4 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86544201 |
WKE AK 42 |
400 x 840 x 230 мм |
stop left, 3 row, 42 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86554201 |
WKE AK 42 R |
400 x 840 x 230 мм |
Stop right, 3 row, 42 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86545601 |
WKE AK 56 |
400 x 990 x 230 мм |
stop left, 4 row, 56 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86555601 |
WKE AK 56 R |
400 x 990 x 230 мм |
Stop right, 4 row, 56 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86547001 |
WKE AK 70 |
400 x 1140 x 230 мм |
70 distribution units, stop left, 5 row, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 21 / 2 x 14 screwless clamping points 1.5 mm? - 4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86557001 |
WKE AK 70 R |
400 x 1140 x 230 мм |
70 distribution units, Stop right, 5-row, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 21 distribution units, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86561401 |
WKE AK 14/2 |
700 x 540 x 230 мм |
stop left, 1-row, 28 modules, Ui=400V, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 28 screwless terminals, 1.5 - 4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F30 for internal flame impingement according to DIN 4102 based on I30, F30 when exposed to flames from the outside in accordance with DIN 4102 E30, can be individually equipped with type-tested operating materials |
86571401 |
WKE AK 14/2 R |
700 x 540 x 230 мм |
Stop right, 1-row, 28 modules, Ui=400V, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 28 screwless terminals, 1.5 - 16 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
F30 for internal flame impingement according to DIN 4102 based on I30, F30 when exposed to flames from the outside in accordance with DIN 4102 E30, Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86562801 |
WKE AK 28/2 |
700 x 690 x 230 мм |
stop left, 2 row, 56 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points 1.5 - 4 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, can be individually equipped with type-tested operating materials |
86572801 |
WKE AK 28/2 R |
700 x 690 x 230 мм |
Stop right, 2 row, 56 distribution units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points 1.5 - 4 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86564201 |
WKE AK 42/2 |
700 x 840 x 230 мм |
stop left, 3 row, 84 modules, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, can be individually equipped with type-tested operating materials |
86574201 |
WKE AK 42/2 R |
700 x 840 x 230 мм |
Stop right, 3 row, 84 modules, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, with cable covering, masking and labelling strips, additional double-membrane seals and other accessories |
F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86565601 |
WKE AK 56/2 |
700 x 990 x 230 мм |
stop left, 4 row, 112 spacing units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, can be individually equipped with type-tested operating materials |
86575601 |
WKE AK 56/2 R |
700 x 990 x 230 мм |
Stop right, 4 row, 112 spacing units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |
86567001 |
WKE AK 70/2 |
700 x 1140 x 230 мм |
stop left, 5 row, 140 spacing units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 6 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, can be individually equipped with type-tested operating materials |
86577001 |
WKE AK 70/2 R |
700 x 1140 x 230 мм |
Stop right, 5-row, 140 spacing units, Ui=400V, 150 mm rail spacing, screwless PE/N terminal rails each with 3 screwable clamping points, 2.5 - 16 mm?, 42 screwless terminals 1,5-4 mm?, elastic entries on top, additional double-membrane seals and other accessories |
F30 for internal flame impingement according to DIN 4102 based on I30, F30 for external flame impingement according to DIN 4102 based on E30, Fire protection small-scale distributors, VDE certificated compliant with EN 61 439 Part 2, VDE tested and certified under specific operating conditions to be compliant with EN 61 439-2, tested compliant with DIN 4102 Part 2 by MPA Dresden, F90 for internal flame impingement according to DIN 4102 based on I90, F90 for external flame impingement according to DIN 4102 based on E90, can be individually equipped with type-tested operating materials |